Coriolis mass flowmeter manufacturer with bjssae.com

Coriolis flow meters factory from China: A high-precision measurement and control system is essential when manufacturing optical fibers. In the burner control application, mass flow devices help control gases that heat the preform and help control thin layer deposition. Furthermore, argon is fed into a furnace to facilitate the drawing process, preventing the furnace element from burning. Pulse modulated sparging produces uniformly sized oxygen bubbles into a bioreactor using mass flow controllers. Mass flow is used in bioreactors to regulate oxygen and CO2 levels. Through precise, low-flow control, the bioreactor is properly oxygenated and toxic carbon dioxide is effectively removed. Discover more details on coriolis meters.

Second, the gas turbine flow meter equipment has strong functions, low power consumption and superior performance. When it is sold in the industry, it is found that the functional advantages of this kind of flowmeter will be more perfect. In many gas distribution stations or gas When promoting in the station, I found that the advantages will be more diversified, and there are more and more advantages. Third, the configuration of the natural gas turbine flow meter instrument is more perfect, and it will be more and more widely used. As long as you take a fancy to the above clarity, it will be more convenient in the process of normal use. After this is used in many gas distribution stations, it is found that the measurement accuracy is higher.

Influence of humidity on measurement results when using vortex meter. The output of the vortex flowmeter is only proportional to the flow velocity of the fluid flowing through the measuring tube. When measuring wet saturated steam, the influence of water droplets on the output of the turbine flow meter is negligible, so it can be considered that the output of the turbine flow meter is entirely caused by the wet flow. Caused by the dry part of the steam. The density of the dry part, whether it is pressure compensation or temperature compensation, can be detected more accurately. The results of steam measurement are often used as the basis for economic settlement between the supply and demand sides. If the two parties agree to settle the fee according to the dry part of the steam and no charge for the condensed water, the impact of the phase change on the measurement is negligible and can be ignored.

The Insertion Density Meters are equiped with the microprocessors inside, so the sensor could complete the signal conditioning, calculation and diagnosis functions, and it does not need the remote eletronic devices for processing. Typical industries applied include the petrochemical industiry, electricity power industry, wine industry, food industry, pharmaceutical industry, and mineral processing (such as, clay, carbonate, silicate, etc. ) For sepecific applications, the Insertion Density Meters are largely used in the interface detection of the multi-product production lines, density detection of the mixed liquid, end monitoring of the reaction kettle, and the separator interface detection.

Thermal mass flow meters are suitable for all industrial and test platform applications that require fast, accurate gas measurement. The insertion thermal mass flow meter directly indicates the mass flow or standardized volume flow of the gas without any additional pressure and temperature compensation. They have impressive high accuracy, short response times and a very wide flow range, with almost no loss of accuracy even at the lowest flow. Discover extra information at https://www.bjssae.com/.

Inner software: For the inner software, we can even customize the inner software with your own company’s name and information. Standard color: If the ordering quantity is big , we can customize the color of the transmitters on the coriolis mass flow meters for you. The standard color is dark grey. We are providing the complete measuring solutions, not only one single unit of coriolis mass flow meter. Sometimes even though it is not the problem of our coriolis mass flow meters or thermal mass flow meter, we will still help you solve the problems.

When the vortex gas flow meter is installed behind the pressure reducing valve, the saturated steam suddenly decompresses greatly, the fluid expands adiabatically, the water droplets partially evaporate, and at the same time absorbs the heat of vaporization from the liquid and vapor phases, reducing the temperature of the vapor and liquid phases. If the temperature is not lowered much or the humidity is higher before evaporation, the temperature will quickly drop to the saturation temperature corresponding to the new pressure, and a new equilibrium will be established. At this time, the steam is still saturated steam. If the pressure drops a lot or the humidity before evaporation If the temperature is lower, the temperature is still higher than the saturation temperature corresponding to the new pressure due to the evaporation of water droplets, and the steam becomes superheated steam.